Technical Data
No. of cable
2/4/6/8/12
16/24
Fiber Model
G.652D/OM3
Loose Tube
Material
PBT
Diameter(±0.06)mm
2.0
2.6
Thickness(±0.03)mm
0.35
0.4
The Max.Core NO./Tube
2/4/6/8/12
16/24
Strength Member
Material
Glass Yarn
Ripcord(Material)
Nylon
Outer Sheath
Material
LSZH
Colour
Black
Thickness(±0.2)mm
1.5
1.5
Cable Diameter(±0.2)mm
5.5
6.0
Cable Wetght(±5)kg/km
40
45
Min. bending radius
Without Tension
10.0×Cable-φ
Under Maximum Tension
20.0×Cable-φ
Temperature range(℃)
Installation
-20~+60
Transport&Storage
-40~+70
Operation
-40~+70
Fiber Colors
No.
1
2
3
4
5
6
Color
Blue
Orange
Green
Brown
Gray
White
No.
7
8
9
10
11
12
Color
Red
Black
Yellow
Violet
Pink
Aqua
No. 13 14 15 16 17 18 Color
Blue+P
Orange+P
Green+P
Brown+P
Gray+P
White+P
No. 19 20 21 22 23 24 Color
Red+P
Black+P
Yellow+P
Violet+P
Pink+P
Aqua+P
"P"means Point mark
The Properties of Single Mode Optical Fiber (ITU-T Rec. G.652.D)
Item Specification Fiber type Single mode Fiber material Doped silica Attenuation coefficient
@ 1310 nm
@ 1383 nm
@ 1550 nm
@ 1625 nm≤ 0.36 dB/km
≤ 0.32 dB/km
≤ 0.22 dB/km
≤ 0.30 dB/kmPoint discontinuity ≤ 0.05 dB Cable cut-off wavelength ≤ 1260 nm Zero-dispersion wavelength 1300 ~ 1324 nm Zero-dispersion slope ≤ 0.092 ps/(nm2.km) Chromatic dispersion
@ 1288 ~ 1339 nm
@ 1271 ~ 1360 nm
@ 1550 nm
@ 1625 nm≤3.5 ps/(nm. km)
≤5.3 ps/(nm. km)
≤18 ps/(nm. km)
≤22 ps/(nm. km)PMDQ (Quadrature average*) ≤0.2 ps/km1/2 Mode field diameter @ 1310 nm 9.2±0.4 um Core / Clad concentricity error ≤ 0.5 um Cladding diameter 125.0 ± 0.7 um Cladding non-circularity ≤1.0% Primary coating diameter 245 ± 10 um Proof test level 100 kpsi (=0.69 Gpa), 1% Temperature dependence
0oC~ +70oC @ 1310 & 1550nm≤ 0.1 dB/km The Properties of Multimode Optical Fiber (ITU-T Rec. OM3)
Characteristic Condition Data Unit Optical properties Attenuation 850nm
1300nm≤2.4
≤0.6dB/km
dB/kmFull injection bandwidth 850nm
1300nm≥1500
≥500MHz•Km
MHz•KmNumerical aperture 0.200±0.015 Zero dispersion wavelength 1295-1340 nm A zero-dispersion slope 1295-1310
1310-1340≤0.105
≤0.000375ps/(nm2.km)
ps/(nm2.km)Group refractive index 850nm
1300nm1.482
1.477The macro bend additional attenuation
100 CircleФ75mm
4 CircleФ30mm850nm
1300nm
850nm
1300nm≤0.5
≤0.5
≤1.0
≤1.0dB
dB
dB
dBGeometric characteristics Core diameter 50±2.5 μm Core roundness ≤5.0 Cladding roundness ≤1.0 % Cladding diameter 125.0±1.0 μm Coating diameter 245±7 μm Coating / package concentricity error ≤10.0 μm Coating roundness ≤6.0 % Core / package concentricity error ≤1.5 μm Fiber length ≤17.6 Km/axis Backscatter characteristics(1300nm) Steps( Mean value of two-way measurement) ≤0.1 dB The irregularity of the length direction and the discontinuity of the point ≤0.1 dB Attenuation inhomogeneity ≤0.08 dB/km Environmental characteristics(850nm、1300nm) Temperature additional attenuation -60℃ ~+85℃ ≤0.1 dB/km Temperature-humidity cycle additional attenuation -10℃ ~+85℃,4%~98% Relative humidity ≤0.1 dB/km Flooding additional attenuation 23℃,30 days ≤0.1 dB/km Dry heat additional attenuation 85℃,30 days ≤0.1 dB/km Hot and humid additional attenuation 85℃ and 85% Relative humidity,30 days ≤0.1 dB/km Mechanical properties Screening tension ≥9.0
≥1.0
≥100N
%
kpsiDynamic fatigue parameters( Nd,Typical value) 27 Application
NO.
Item
Requirement
1
Allowable Tensile Strength
Short Term
1000N
Long Term
400 N
2
Allowable Crush Resistance
Short Term
1000 (N/100mm)
Long Term
300 (N/100mm)
Main Mechanical & Environmental Performance Test
Item
Test Method
Acceptance Condition
Tensile Strength
IEC 794-1-2-E1- Load: Short term tension
- Length of cable: about 50m- Loss change ≤ 0.1 dB @1550 nm
- No fiber break and no sheath damage.Crush Test
IEC 60794-1-2-E3- Load: Short term crush
- Load time: 1min- Loss change ≤ 0.05dB@1550nm
- No fiber break and no sheath damage.Impact Test
IEC 60794-1-2-E4- Points of impact: 3
- Times of per point: 1
- Impact energy: 5J- Loss change ≤ 0.1dB@1550nm
- No fiber break and no sheath damage.Temperature Cycling Test
YD/T901-2001-4.4.4.1- Temperature step:
+20oC→-40oC→+70oC →+20oC
- Time per each step: 12 hrs
- Number of cycle: 2- Loss change ≤ 0.05 dB/km@1550 nm
- No fiber break and no sheath damage.Sheath marking
The color of marking is white, but if the remarking is necessary, the white color marking shall be printed newly on a different position.
An occasional unclear of length marking is permitted if both of the neighboring markings are clear.
The both cable ends are sealed with heat shrinkable end caps to prevent water ingress.
Factory & Warehouse
-
Factory & Warehouse
Factory & Warehouse -
Factory & Warehouse
Factory & Warehouse -
Factory & Warehouse
Factory & Warehouse
FAQ
Q:
How many years have you been in this industry
A:
Q:
What is your usual shipping time?
A:
Q:
Does your product have warranty service?
A:
Q:
Can we send samples by mail?
A:
Inquiry
Please fill in your contact information carefully, and we will provide you with one-on-one VIP service to answer your questions in detail!