1.Scope of application
This Installation Manual suits for the Fiber Optic Splice Closure (Hereafter abbreviated as FOSC), as the guidance of proper installation.
The scope of application is: aerial, underground, wall-mounting, duct-mounting and handhole- mounting. The ambient temperature ranges from –40℃ to +65℃.
2. Basic structure and configuration
2.1 Dimension and capacity
Outside dimension (Height x Diameter) 515mm×310mm Weight (excluding outside box) 3000 g— 4600g Number of inlet/out ports 7 pieces in general Diameter of fiber cable Φ5mm~Φ38 mm Capacity of FOSC Bunchy: 24-288(cores), Ribbon: up to864(cores) 2.2 Main components
No. Name of components Quantity Usage Remarks 1 FOSC cover 1piece Protecting fiber cable splices in whole Height x Diameter
360mm x 177mm
2 Fiber optic splice tray (FOST) Max. 12 trays (bunchy)
Max. 12 trays (ribbon)
Fixing heat shrinkable protective sleeve and holding fibers Suitable for: Bunchy:12,24(cores) Ribbon:6 (pieces) 3 Fiber holding tray 1 pcs Holding fibers with protective coat 4 Base 1set Fixing internal and external structure 5 Plastic hoop 1 set Fixing between FOSC cover and base 6 Seal fitting 1 piece Sealing between FOSC cover and base 7 Pressure testing valve 1 set After inject air, it is used for pressure testing and sealing testing Configuration as per requirement 8 Earthing deriving device 1 set Deriving metal parts of fiber cables in FOSC for earthing connection Configuration as per requirement 2.3 Main accessories and special tools
No. Name of accessories Quantity Usage Remarks 1 Heat shrinkable protective sleeve Protecting fiber splices Configuration as per capacity 2 Nylon tie Fixing fiber with protective coat Configuration as per capacity 3 Heat shrinkable fixing sleeve (single) Fixing and sealing single fiber cable Configuration as per requirement 4 Heat shrinkable fixing sleeve (mass) Fixing and sealing mass of fiber cable Configuration as per requirement 5 Branching clip Branching fiber cables Configuration as per requirement 6 Earthing wire 1 piece Putting through between earthing devices 7 Desiccant 1 bag Put into FOSC before sealing for desiccating air 8 Labeling paper 1 piece Labeling fibers 9 Special wrench 1 piece Tightening nut of reinforced core 10 Buffer tube decided by customers Hitched to fibers and fixed with FOST, managing buffer. Configuration as per requirement 11 Aluminum-foil paper 1 piece Protect the bottom of FOSC 3. Necessary tools for installation
3.1 Supplementary materials (to be provided by operator)
Name of materials Usage Scotch tape Labeling, temporarily fixing Ethyl alcohol Cleaning Gauze Cleaning 3.2 Special tools (to be provided by operator)
Name of tools Usage Fiber cutter Cutting off fiber cable Fiber stripper Strip off protective coat of fiber cable Combo tools Assembling FOSC 3.3 Universal tools(to be provided by operator)
Name of tools Usage and specification Band tape Measuring fiber cable Pipe cutter Cutting fiber cable Electrical cutter Take off protective coat of fiber cable Combination pliers Cutting off reinforced core Screwdriver Crossing/Paralleling screwdriver Scissor Waterproof cover Waterproof, dustproof Metal wrench Tightening nut of reinforced core 3.4 Splicing and testing instruments (to be provided by operator)
Name of instruments Usage and specification Fusion Splicing Machine Fiber splicing OT DR Splicing testing Provisional splicing tools Provisional testing Fire sprayer Sealing heat shrinkable fixing sleeve Notice: The above-mentioned tools and testing instruments should be provided by the operators themselves.
4. Installation flow chart

5. The process of installing FOSC.
5.1 Step One - Open the closure
5.1.1Cleaning the locale and determine where to install the FOSC and then place fiber cables required.
5.1.2Check whether the main components and accessories have been well prepared inside the package.
5.1.3Open the closure
① Demount hoop fixing bolt and pull hoop locking system out, then proceed in demounting the hoop.
② Pull the FOSC cover upwards out, installation could begin.
5.1.4 See Drawing 1
Important issues: If the weather condition is not good enough, then a tent must be pitched for waterproof and dustproof.

5.2Step Two -Determine length of fiber cable to be fixed and stripped inside FOSC
5.2.1If all fibers are for branch splicing, please refer to Drawing 2(A) for stripping length.
5.2.2If some fibers are for straight-through, while others are for branch splicing, please refer to Drawing 2(B) for stripping length.
5.2.3See Drawing 2.
Important issues: 1. Reserve enough length of fiber cable to be spliced.2. Stripping length also could be decided by customers according to installation requirement
5.3 Step Three –Strip off protective coat of fiber cable and fiber
5.3.1 Strip off protective coat of fiber cable from the temp. locating mark with the cutter and the stripper, please refer to Drawing 2 for stripping length. Stripping length also could be decided according to installation requirement
5.3.2 See Drawing 3.
Important issues: If it is difficult to pull all the protective coat of fiber cable at one time, strip it off section by section to avoid fiber breakage.

5.4 Step Four – Separate fiber cores and prepare work prior to fixing fiber cable.
5.4.1 Wind 2 layers of insulation tape on protective coat of fiber core for protection. Meanwhile, get rid of the stuffing to separate fiber core and clean them. Form a ring with the diameter of 100mm or so and fix it on the fiber temporarily by adhesive tape.
5.4.2 Depending on fiber cable stripped, the following two cases are available.
① All fibers are to be branched after being spliced completely.
② Some of fibers are for straight-through after being winded, while the others are for branch splicing.
5.4.3The FOSC is provided with 3 single entry/exit tubes which suit for single fiber cables with max. diameter ф16mm and 1 mass entry/exit tube which suits for 1 piece of fiber cable with max. diameter ф 25mm or 2 pieces of fiber cables with max.diameter ф 21mm or multi-pieces of fiber cables with short diameter.
5.4.4Mass entry/exit tube is required if some fibers are for straight-through
5.4.5The corresponding entry/exit tube cover could be slightly knocked out withscrewdriver from inside to outside according to number and diameter of fiber cable required.
5.4.6Reserve reinforced core in 70mm length and cut off the unnecessary ones.
5.4.7See Drawing 4 and Drawing 5.
Important Issues:Entry/exit tubes are to be selected accurately to make it easy for splicing and sealing.
5.5 Fix reinforced core, and pyrocondense, fix and seal fiber cable.
5.5.1 Insert fiber cable into the corresponding heat shrinkable fixing tube, further insert the them into entry/exit tube at the bottom of FOSC.
5.5.2 Demount fixing nut of reinforced core with a special wrench (plastic one), which is to be inserted into the fixing slot afterward and tighten it. Then retighten it with a metal wrench (the metal wrench is to be provided by operator).
5.5.3 Hitch heat shrinkable fixing sleeve to the fiber cable till its root by hand.
5.5.4 Please refer to Drawing 5 for installing branching clip.
5.5.5 Heat heat shrinkable fixing sleeve with fire sprayer to make it hugging entry/exit tube and fiber cable to reach complete sealing.
5.5.6 See Drawing 5
important issue: 1. Fixing nut of reinforced core should be tightened.2. While heating, heat shrinkable fixing tube should shrink evenly, and there should be no bubbles, pores and other defects inside the tube.

5.6 Step Six - Splice fibers
5.6.1 Follow user manual of fusion splicing machine to splice fiber.
Important issue: pay attention to the twist and bend of fiber
5.7 Step Seven -Install heat shrinkable protective sleeve and house fibers.
5.7.1 When having completed splicing the fibers, the first fiber ring should be housed on the farthest side of FOST, the remaining fiber optic should be winded, forming a ring with diameter not less than 80mm. then put it into FOST (Fiber Optic Splice Tray) together with heat shrinkable protective sleeve.( Firstly fix heat shrinkable protective sleeve into the slot, then enlarge the diameter of
fiber ring properly.)
5.7.2 see Drawing 6
Important issue: pay attention to the twist and bend of fiber.

5.8Step Eight - Check up comprehensivelyTo ensure the technical requirements, the following instructions must be followed:
5.8.1Fibers with protective coat are fixed with nylon tie at the entrance of FOST.
5.8.2Grommet should be pressed from inside to outside in order to properly install FOST.
5.8.3Straight-through and reserved fibers with protective coat should be winded to the fiber holding tray.
5.8.4Check whether the internal tighteners and fixing nut of reinforced core are well tightened.
5.8.5Check whether seal fitting is installed neatly and smoothly.
5.8.6Check whether heat shrinkable fixing sleeve is reliable and sealing completely.
5.8.7See Drawing 7.
Important issues: If any problems occur, they should be solved right away.
5.9 Step Nine – Assemble FOSC housing and fix FOSC
5.9.1 Put desiccant into FOSC.
5.9.2 Put FOSC cover on base directly.
5.9.3 Install plastic hoop between FOSC cover and base, tighten hoop locking system,which is to be fixed by hoop fixing bolt then.
5.9.4 FOSC installation ① Aerial application: fix metal hoop and transom to the pole. Please refer to Drawing 8② Wall mounting application: fix the bracket on the wall with bolt. (metal hoop is not
required. ③ Underground application: metal hoop is not required.
5.9.5 See drawing 8
Important issues: 1. Pay attention while installing plastic hoop. 2. The specification of bolt for fixing the bracket is M8.
6.Fiber Optic Splice Closures (FOSC) inspecting and testing items
Inspecting item Technical Requirements Inspecting type Routine test (Before leaving factory) Type test Package Each small package contains one fiber optic splice closure, together with its accessories, tools, installation manual and packing list. full At least 3 sets sampled each time Appearance Intact in shape, no burrs, bubbles, chaps, pores, warps, impurities and other defects, all background colors should be even and continual. Sign There is a clear sign on the housing, such as name and model of the product, etc. Fiber storage device The fibers reserved are to be winded in fiber optic splice tray (FOST), the length of fibers housed in FOST is >1.6m, the curved radius is >30mm. During the installation and maintenance, there should be no attenuation on fibers. At least 3 sets sampled each time Electrical jointing device Inside FOSC: metallic components of fiber cables has the functions of electrical putting through, earthing connection and disconnecting. It is possible to install earthing deriving device outside the housing Sealing performance After sealing according to the stipulated operation procedures, the injected air pressure is 100KPa±5Kpa, when immersed in clean water of normal temperature for 15 minutes, there should be no air bubbles, then observed for 24 hours, there should be no change of air pressure. Re-sealing performance After reopening and resealing according to the stipulated operation procedures, the injected air pressure is 100KPa±5Kpa, when immersed in clean water of normal temperature for 15 minutes, there should be no air bubbles, then observed for 24 hours, there should be no change of air pressure. Pull Bearing pull is ≧ 800N at axle orientation, there should be no breakage on the housing. Punching Bearing pressure of 2000N/10cm for 1 minutes, there should be no breakage on the housing Impact Bearing impact energy of 16N•m, 3 times of impacts there should be not breakage on the housing Bending The spot between the FOSC and seal fitting can bear bending tension of 150N at bending angle of ±450 for 10 circles, there should be no breakage on the housing Torsion Bearing torsion 50N•m, 10 circle at torsion angle±900,
There should be no breakage on the housing.
Temperature circle Injected air pressure of 60KPa±5 KPa, the temperature circle ranging from -40℃~+65℃, 10 times of the circular tests (one circular consists of high temperature for 2 hours + indoor temperature for 2 hours + low temperature for 2 hours + indoor temperature for 2 hours ) when the pressure declines, the amplitude is ≦5Kpa, immerse the swatch in clean water of normal temperature for 15 minutes, there should be no air bubbles. Voltage resistance strength After sealing the FOSC according to the stipulated operation procedures, immerse it in clean water of normal temperature in 1.5m depth for 24 hours, there should be no breakdown or arc over between the metallic components of the FOSC, between metallic components and the ground at DC 15KV for 1 minutes. Isolating resistance After sealing the FOSC according to stipulated operation procedure, immerse it in clean water in 1.5m depth for 24h, the isolating resistance between the metallic components of the FOSC, between the metallic components and the ground should be ≧ 2×104MΩ.
Factory & Warehouse
-
Factory & Warehouse
Factory & Warehouse -
Factory & Warehouse
Factory & Warehouse -
Factory & Warehouse
Factory & Warehouse
FAQ
Q:
How many years have you been in this industry
A:
Q:
What is your usual shipping time?
A:
Q:
Does your product have warranty service?
A:
Q:
Can we send samples by mail?
A:
Inquiry
Please fill in your contact information carefully, and we will provide you with one-on-one VIP service to answer your questions in detail!